Drager Babylog 8000 plus Neonatal Intensive Care Ventilation YOM: 2009

Drager Babylog 8000 plus Neonatal Intensive Care Ventilation YOM: 2009

Location:Oldham, United Kingdom

Description

Includes:

-Babylog 8000 plus Neonatal Intensive Care Ventilation YOM: 2009


Key Features:


  • Advanced Neonatal Ventilation: Designed specifically for respiratory support of neonates and premature infants in intensive care environments.
  • Multiple Ventilation Modes: Supports IPPV/IMV, SIPPV, SIMV, PSV and CPAP ventilation modes.
  • Volume Guarantee (VG): Helps maintain a consistent preset tidal volume while adapting inspiratory pressure to changing lung conditions.
  • High-Frequency Ventilation: Provides an optional HFV function for specialised neonatal respiratory support.
  • Pressure Support Ventilation: Supports spontaneous breathing and can assist the weaning process.
  • Compact Design: Practical configuration suitable for Neonatal Intensive Care Units (NICUs).


Technical Highlights:


Precise Neonatal Respiratory Support

The Babylog 8000 Plus is engineered for sensitive neonatal ventilation, with accurate synchronisation and monitoring of very small tidal volumes.

Flexible Ventilation Therapy

Its combination of conventional ventilation modes, Volume Guarantee, PSV, CPAP and optional HFV provides flexibility for different neonatal respiratory requirements.

Leak Compensation & Spontaneous Breathing

Pressure Support Ventilation incorporates automatic leak compensation, helping maintain effective support while allowing the infant greater control over breathing.


Applications:


The Dräger Babylog 8000 Plus is suitable for:

  • Neonatal Intensive Care Units (NICU)
  • Premature and critically ill infants
  • Neonatal respiratory distress management
  • Invasive and non-invasive respiratory support
  • Weaning from mechanical ventilation
  • Specialised high-frequency ventilation


Key Benefits:


  • Purpose-built neonatal ventilation
  • Accurate and sensitive respiratory support
  • Flexible ventilation modes
  • Volume Guarantee for controlled tidal volumes
  • Supports spontaneous breathing and weaning
  • Compact and practical NICU design
  • Established Dräger ventilation technology


Why Choose Dräger Babylog 8000 Plus?


The Dräger Babylog 8000 Plus Ventilator, a 2009 model, is a key instrument in neonatal intensive care, designed specifically for premature and newborn infants. This ventilator offers modes such as CPAP, IMV, SIMV, and volume-controlled ventilation, delivering precise respiratory support with minimal stress on delicate lungs. Its compact, user-friendly design ensures seamless integration into NICU environments, supporting clinical staff with intuitive LCD controls and real-time monitoring of airway pressure, flow, and volume. Engineered for reliability, the Dräger Babylog 8000 Plus provides consistent performance, making it a trusted choice for healthcare providers. It is equipped with advanced technologies, including BabyFlow® nasal CPAP and pressure support ventilation, enhancing the safety and efficacy of neonatal care. The ventilator's design simplifies operation and allows healthcare professionals to focus on patient care, even in high-pressure situations.

Specifications

Year2009
ConditionUsed
ManufacturerDrager
ModelBabylog 8000 Plus
Stock Number7582962
The Dräger Babylog 8000 Plus Neonatal Ventilator (YOM2009) is a trusted cornerstone for neonatal intensive care units, delivering gentle and precise respiratory support for the most vulnerable patients. Engineered for premature and newborn infants, this ventilator combines advanced technology with user-friendly controls to ensure optimal ventilation with minimal stress. Its compact design, reliable performance, and specialized neonatal features make it an essential tool for NICU clinicians aiming to provide life-saving care with confidence and ease.
Ventilation ModesCPAP, IMV, SIMV, and volume-controlled ventilation
Flow RangeAdjustable for neonatal precision, up to 30 L/min
MonitoringReal-time airway pressure, flow, and volume monitoring
DisplayClear LCD screen with intuitive controls
Why Choose the Dräger Babylog 8000 Plus Ventilator YOM2009
Tailored Neonatal VentilationDesigned specifically for premature and newborn infants, it delivers gentle, precise ventilation to protect delicate lungs while ensuring effective respiratory support.
Advanced MonitoringReal-time data on airway pressure, flow, and volume empowers clinicians to make informed adjustments, optimizing outcomes in critical neonatal care.
User-Friendly DesignThe intuitive LCD interface simplifies operation, allowing NICU staff to focus on patient care even during high-pressure situations.
Compact and ReliableIts space-saving design fits seamlessly into busy NICU environments, while its robust engineering ensures consistent performance for long-term use.
Warranty14 Days Once Delivered
VAT StatusPrice Exlcudes VAT