Medtronic NIM-Response 3.0 REF 8253200

Medtronic NIM-Response 3.0 REF 8253200

Location:Oldham, United Kingdom

Description

Includes:

-Medtronic NIM-Response 3.0 REF: 8253200


Key Features:


  • Nerve Integrity Monitoring: Designed for intraoperative EMG nerve monitoring during surgical procedures.
  • Four-Channel Monitoring: Supports monitoring of up to four nerve-muscle combinations simultaneously.
  • Touchscreen Interface: High-contrast graphical touchscreen provides convenient control and monitoring.
  • Real-Time EMG Feedback: Provides audible and visual alerts when changes in nerve function are detected.
  • Artifact Detection: Includes stimulus-artifact rejection and electrocautery interference monitoring.
  • Electrode Checking: Automatic electrode impedance checking helps verify electrode connectivity.
  • Flexible Stimulation: Provides digitally controlled stimulation with adjustable current settings.


Technical Highlights:


The Medtronic NIM-Response 3.0 is an intraoperative nerve monitoring system designed to help surgeons locate, identify and monitor motor nerve function. It features four monitoring channels, adjustable EMG sensitivity, automatic artifact detection and touchscreen-controlled stimulation.

The system supports 0–30 mA constant-current stimulation, with selectable pulse duration and stimulation rates. Its monitoring capabilities are particularly suited to ENT, head and neck and skull-base procedures.


Applications:


The NIM-Response 3.0 can be used for intraoperative nerve monitoring in procedures including:

  • ENT and head & neck surgery
  • Thyroid and neck procedures
  • Skull-base surgery
  • Intracranial and extracranial procedures
  • Neck dissections
  • Selected procedures involving cranial and peripheral motor nerves


Key Benefits:


  • Helps support nerve identification and functional monitoring during surgery.
  • Provides real-time EMG information with audible and visual feedback.
  • Four-channel capability allows monitoring of multiple nerve-muscle combinations.
  • Touchscreen operation supports straightforward intraoperative control.
  • Built-in artifact detection and electrocautery monitoring help maintain reliable monitoring.
  • Compact design makes it suitable for integration into an operating-room environment.


Why Choose Medtronic NIM-Response 3.0?


The Medtronic NIM-Response 3.0 REF:8253200 is a used neurological monitoring device designed to assist surgeons by providing real-time feedback on nerve health during various procedures. Built by Medtronic, this system offers reliable intraoperative nerve monitoring, crucial for surgeries where nerve integrity may be at risk. Its effective response system ensures that any potential nerve disruptions are promptly detected, allowing for immediate surgical adjustments, thereby enhancing patient safety and outcomes. This model is known for its user-friendly interface and precise monitoring capabilities, making it an essential tool in operating rooms. The Medtronic NIM-Response 3.0 is equipped to support an array of surgeries, with features tailored for adaptability across different neurological procedures. Although it is a used unit, it maintains excellent functionality and meets the high standards set by Medtronic for performance and durability. Ideal for healthcare facilities looking to upgrade their nerve monitoring equipment without the expense of new devices, the Medtronic NIM-Response 3.0 ensures a blend of performance and practicality. It remains a trusted choice for surgeons who require reliable and accurate intraoperative monitoring.

Specifications

ManufacturerMedtronic
ModelNIM-Response 3.0 REF 8253200
ConditionUsed
Stock Number7977567
Touchscreen InterfaceHigh-contrast graphical touchscreen provides
Bandpass15 Hz–1.85 kHz
Stimulus WaveformMonophasic square pulse
Stimulation TypeConstant current
Stimulation Range0–30 mA
Pulse Duration50, 100, 150, 200 or 250 µs