Toshiba PLT-704SBT Linear Ultrasound Probe YOM: 2012

Location:Oldham, United Kingdom
Description
Includes:
- Toshiba PLT-704SBT Linear Probe
Product Details:
- Manufacturer: Toshiba
- Product Name: Linear Ultrasound Probe
- Model: PLT-704SBT
- Year of Manufacture: 2012
- Probe Type: Linear Array Transducer
- Primary Application: Peripheral Vascular Imaging
- Additional Application: Small Parts Imaging, as identified in manufacturer transducer documentation.
- Imaging Technology: High-frequency ultrasound transducer technology.
- Configuration: Probe with attached cable and connector, as pictured.
Key Features:
- High-Frequency Linear Array Technology
The Toshiba PLT-704SBT is a 7.5 MHz linear ultrasound transducer designed for high-frequency ultrasound imaging, particularly in peripheral vascular examinations.
- Wide Frequency Selection
The manufacturer specifies a frequency range of 4.8–11.0 MHz, providing multiple frequency selections for different imaging requirements.
- Peripheral Vascular Imaging
Designed for peripheral vascular ultrasound examinations, supporting the assessment of vascular structures.
- Approximately 38 mm Field of View
The transducer features an approximately 38 mm field of view width, as specified in Toshiba's product documentation.
- Tissue Harmonic Imaging Support
Manufacturer documentation identifies Tissue Harmonic Imaging (THI) frequency selections for this probe, providing additional imaging options when supported by the connected ultrasound system.
- Doppler Imaging Frequency Support
The manufacturer also documents Doppler frequency selections for the PLT-704SBT, supporting its intended vascular imaging applications when used with a compatible ultrasound system.
- Dedicated Probe Configuration
The PLT-704SBT features a linear transducer configuration with an integrated cable and system connection interface.
Clinical Applications:
The Toshiba PLT-704SBT Linear Ultrasound Probe is designed primarily for peripheral vascular imaging and is suitable for the following examination areas, subject to compatible system configuration:
- Peripheral Vascular Ultrasound
Used for ultrasound examinations of peripheral blood vessels, including vascular assessment of the limbs.
- Carotid Vascular Assessment
Linear transducers of this type are used in carotid ultrasound examinations to assess superficial vascular structures.
- Small Parts Imaging
The probe's high-frequency linear configuration can support imaging of superficial anatomical structures, subject to the manufacturer's specified applications and connected system capabilities.
- Musculoskeletal Ultrasound
Linear ultrasound technology can be used for superficial musculoskeletal examinations, including tendons and other accessible structures. Confirm the specific application against the connected system's approved configuration.
Suitable Clinical Environments:
- Vascular imaging departments
- Diagnostic ultrasound departments
- Radiology and medical imaging centres
- Hospitals and specialist diagnostic clinics
Key Benefit:
- Dedicated Vascular Imaging Capability
Designed specifically for peripheral vascular ultrasound applications, making it a relevant transducer option for facilities performing vascular examinations.
- Flexible Frequency Selection
The manufacturer-specified 4.8–11.0 MHz frequency range offers different imaging selections to accommodate examination requirements.
- Established Toshiba Probe Model
The PLT-704SBT is an established Toshiba linear transducer model, providing buyers with a clearly identifiable model for equipment sourcing and compatibility checks.
- Integrated Probe Assembly
The supplied photographs show the probe with its attached cable and connector, allowing prospective buyers to review the physical configuration before making an enquiry.
- Additional Imaging Options
Manufacturer-documented THI and Doppler frequency selections provide further imaging options when supported by the connected ultrasound platform.
Why Choose Toshiba PLT-704SBT Linear Probe?
The Toshiba PLT-704SBT Linear Ultrasound Probe (YOM 2012) is an option for healthcare organisations and medical equipment buyers seeking a Toshiba linear transducer for peripheral vascular imaging.
Its manufacturer-documented 7.5 MHz centre frequency, 4.8–11.0 MHz frequency range and approximately 38 mm field of view make it a specifically identifiable probe for buyers looking for this model.
Key reasons to consider this equipment include:
- Recognised Manufacturer: Toshiba medical imaging equipment.
- Specific Model Identification: PLT-704SBT linear ultrasound transducer.
- Established Imaging Configuration: Designed for peripheral vascular applications.
- Frequency Flexibility: Manufacturer-specified 4.8–11.0 MHz frequency range.
- Documented Technical Features: THI and Doppler frequency selections.
- Clear Product Photographs: Actual equipment images showing the probe, cable, connector and identification markings.
- Manufacture Year: 2012
Whether sourcing a replacement Toshiba ultrasound probe or looking for a specific linear transducer for an existing compatible ultrasound system, the PLT-704SBT offers a clearly identified model for consideration.
Contact Hessen Medical Ltd to enquire about availability, current condition, pricing and compatibility with your existing Toshiba ultrasound equipment.
Specifications
| Year | 2012 |
| Condition | Used |
| Manufacturer | Toshiba |
| Model | PLT-704SBT |
| Stock Number | 9778536 |
| Availability | In stock |
| VAT Status | Price excludes VAT |
| Warranty | 14 Days Once Delivered |
| Shipping | Worldwide shipping available |
| About | The Toshiba PLT-704SBT is a 7.5 MHz linear ultrasound transducer manufactured in 2012. Designed primarily for peripheral vascular imaging, it features a manufacturer-specified 4.8–11.0 MHz frequency range and approximately 38 mm field of view. |
| Ideal for | Suitable for hospitals, vascular imaging departments, diagnostic ultrasound centres and specialist medical facilities seeking a Toshiba PLT-704SBT linear probe for peripheral vascular examinations, subject to ultrasound system compatibility. |









